The APC Back-UPS Pro 1000S delivers reliable battery backup and surge protection, safeguarding your valuable electronics with ten NEMA outlets and USB charging.
Overview of the BR1000G Model
The APC Back-UPS Pro BR1000G is a robust, line-interactive UPS designed for professionals and discerning home users. It features 10 NEMA outlets – four offering surge-only protection, and six with battery backup. Two USB charging ports conveniently power devices. A clear LCD interface displays crucial information, while hot-swappable batteries ensure uninterrupted power during maintenance, as detailed in the comprehensive user manual.
Key Features and Benefits
This APC Back-UPS Pro 1000 boasts several advantages, including reliable battery backup and superior surge protection. The hot-swappable battery design allows for easy replacement without downtime. Its LCD display provides real-time status updates, and the PowerChute software enables safe system shutdown. Registration ensures warranty coverage, protecting your investment for years to come.
Unboxing and Inspection
Carefully inspect the APC Back-UPS Pro 1000 upon receipt for any physical damage, and verify all package contents are present before initial setup;
Package Contents Verification
Confirm the package includes the APC Back-UPS Pro 1000 unit itself, a user manual providing installation and safety guidelines, and potentially a registration card for warranty coverage. Check for included software, like PowerChute, on a CD or download instructions. Ensure all accessories, such as any connecting cables, are present and undamaged before proceeding with setup. Missing components should be reported immediately to the retailer or APC support.
Physical Inspection for Damage
Carefully inspect the UPS for any visible signs of shipping damage, including dents, cracks, or broken parts. Examine the outlets and USB ports for physical defects. Verify the LCD display is intact and functional. If damage is detected, do not attempt to install or operate the unit; immediately contact the seller and APC support to arrange for a replacement or repair, documenting the damage with photos.

Installation and Setup
Proper installation ensures optimal protection. Connect the UPS to a grounded outlet, then connect your devices, and perform the initial self-test for verification.
Connecting the UPS to Power
Ensure the UPS is switched off before connecting it to a grounded wall outlet. Avoid using extension cords or power strips, as they negate the surge protection benefits. Verify the outlet voltage matches the UPS input voltage requirements. A direct connection is crucial for reliable power backup and optimal performance during outages, safeguarding connected equipment.
Connecting Devices to the UPS
Plug your computer, monitor, and other essential peripherals into the battery backup outlets on the UPS. Surge-protected-only outlets are ideal for less critical devices like printers. Avoid exceeding the UPS’s total wattage capacity to prevent overload. Proper connection ensures continuous operation during power failures, protecting data and hardware.
Initial Power-On and Self-Test
After connecting devices, press the power button to activate the UPS. The unit will automatically perform a self-test, verifying battery functionality and alarm operation. Observe the LCD display for test results; a successful test indicates readiness. Regular self-tests ensure the UPS is prepared for power outages, providing reliable protection.
Understanding the LCD Display
The LCD provides crucial information, including battery status, load level, and input/output conditions, allowing users to monitor the UPS’s performance at a glance.
Interpreting Display Icons
The LCD screen utilizes various icons to communicate the UPS status effectively. A battery icon indicates charge level, while an outlet leaf signifies surge protection is active. Power status, load capacity, and alarm conditions are also displayed using distinct symbols. Refer to the comprehensive user manual for a detailed explanation of each icon, ensuring proper understanding of the UPS’s operational state and any potential issues requiring attention.
Battery Status Indicators
The LCD panel provides clear battery status indicators, crucial for proactive maintenance. These include percentage of battery charge, estimated runtime remaining under current load, and battery health. A low battery warning alerts users to potential power outages. Regularly monitoring these indicators helps anticipate battery replacement needs, ensuring uninterrupted power protection for connected devices and preventing unexpected downtime.

Battery Management and Replacement
Convenient, easy-to-connect, hot-swappable battery modules allow replacement without powering down equipment, ensuring continuous protection and minimizing disruption.
Battery Life Expectancy
The typical battery lifespan within the APC Back-UPS Pro 1000 is approximately 3 to 5 years, though this can vary significantly based on environmental factors and usage patterns. Higher temperatures and frequent discharge cycles will reduce battery life. Regular self-tests, as recommended by APC, help monitor battery health and predict necessary replacements, ensuring continued reliable power protection for connected devices.
Hot-Swappable Battery Replacement Procedure
The APC Back-UPS Pro 1000 features convenient, hot-swappable battery modules. To replace, simply power on a compatible replacement battery, then align and insert it into the UPS bay while the unit is running. The UPS automatically switches to the new battery without interrupting power to connected equipment, ensuring continuous operation during maintenance.
Surge Protection Features
This UPS offers robust surge protection technology, shielding devices from damaging voltage spikes via ten NEMA outlets, ensuring reliable power and component safety.
Surge Protection Technology Explained
The APC Back-UPS Pro 1000 employs advanced surge protection to defend connected equipment against damaging electrical disturbances. This technology diverts excess voltage away from sensitive electronics, preventing potential harm from spikes or surges. It utilizes various components, including metal oxide varistors (MOVs), to clamp voltage to safe levels. This safeguards computers, peripherals, and other valuable devices, extending their lifespan and ensuring operational stability during unpredictable power events.
NEMA Outlet Types and Functionality
The APC Back-UPS Pro 1000 features ten NEMA outlets, offering versatile connectivity. Four provide surge-only protection, ideal for less critical devices. The remaining six outlets offer both battery backup and surge protection, safeguarding essential equipment during power outages. Understanding these distinctions ensures optimal device protection and efficient power management, maximizing the UPS’s capabilities.

Software and Connectivity
PowerChute software enables advanced UPS management, while integrated USB charging ports conveniently power your mobile devices, enhancing usability and control.
PowerChute Software Installation
To install PowerChute, download the software from the APC website, ensuring compatibility with your operating system. Run the installer and follow the on-screen prompts, connecting the UPS via USB when requested. Configure settings for automatic shutdown during extended outages, customizing runtime preferences. Regularly update PowerChute for optimal performance and security enhancements, maximizing your UPS’s protective capabilities;
USB Charging Port Usage
The APC Back-UPS Pro 1000 features two USB charging ports for convenient device power. These ports provide a regulated 5V output, ideal for smartphones, tablets, and other USB-powered accessories. Charging continues even during power outages, though battery runtime will be affected. Avoid connecting high-draw devices to conserve battery capacity for critical equipment.

Troubleshooting Common Issues
Addressing typical problems like the UPS failing to power on or batteries not charging is crucial for maintaining uninterrupted power and device protection.
UPS Not Powering On
If the UPS fails to power on, first verify the power cord is securely connected to both the UPS and a working wall outlet. Confirm the power switch is in the “On” position. Check the battery connection; a loose connection prevents startup. If still unresponsive, attempt a reset by disconnecting all connected devices and then powering on the UPS. A faulty battery or internal issue may require professional service.
Battery Not Charging
If the battery isn’t charging, ensure the UPS is connected to a functioning power outlet and is switched on. Examine the LCD display for battery-related error messages. A failing battery is a common cause; consider a hot-swappable replacement. Prolonged power outages or an old battery can also hinder charging. Contact support if the issue persists.

Safety Precautions
Always follow general electrical safety guidelines when installing and using the UPS, preventing hazards and ensuring proper operation for reliable power protection.
General Safety Guidelines
To ensure safe operation, inspect the UPS upon receipt for any physical damage. Avoid operating in excessively humid or dusty environments. Do not connect the UPS to power sources with voltage fluctuations. Regularly check the battery status via the LCD display. Always disconnect devices before performing battery replacement, utilizing the hot-swappable feature carefully.
Preventing Electrical Hazards
Always ground the UPS properly to prevent shock hazards. Do not open the UPS casing, as hazardous voltage levels exist inside. Avoid using extension cords or adapters, connecting devices directly to the UPS. Replace batteries with APC-approved models only. Disconnect the UPS before cleaning, and never use liquids.
Warranty and Registration
Register your APC Back-UPS Pro 1000 for warranty coverage; complete and return the warranty registration card promptly to activate your product’s benefits.
Warranty Coverage Details
APC’s warranty for the Back-UPS Pro 1000 varies by region, generally covering defects in materials and workmanship for a specified period from the purchase date. This typically includes parts and labor, but excludes battery wear and tear. The warranty is void if the unit is misused, modified, or disassembled without authorization. Proof of purchase is required for all warranty claims; registration aids in faster processing.
Product Registration Process
Registering your APC Back-UPS Pro 1000 is simple and recommended! Locate the model number on the unit, then visit the Schneider Electric APC website. Find the product registration form and complete it with your details and purchase information. Registration confirms ownership, streamlines warranty claims, and provides access to important product updates and support resources.

Technical Specifications
The APC Back-UPS Pro 1000 offers 1000VA/600W capacity, with a standard input/output voltage of 120V and a battery runtime dependent on load.
Input/Output Voltage and Frequency
The APC Back-UPS Pro 1000 is designed for 120V / 60Hz operation, typical for North American power grids. Input voltage range is commonly 92-126V, automatically adjusting to maintain stable output. The unit delivers a pure sine wave output, crucial for sensitive electronics. Frequency conversion isn’t a primary feature; it’s designed to regulate within the standard 60Hz frequency.
Battery Capacity and Runtime
The APC Back-UPS Pro 1000 utilizes a sealed lead-acid battery, offering substantial runtime during power outages. Typical runtime for a full load (1000VA/600W) is around 5-10 minutes, sufficient for safe shutdown. Lower loads extend runtime considerably. Battery capacity is approximately 12V/9Ah, providing dependable power. Hot-swappable design allows for easy replacement.

Maintenance and Care
Regularly clean the UPS exterior with a dry cloth, ensuring proper ventilation. Avoid extreme temperatures and humidity for optimal performance and longevity.
Cleaning the UPS
To ensure reliable operation, periodically clean the exterior of your APC Back-UPS Pro 1000. Always disconnect the UPS from the power source before cleaning. Use a soft, dry cloth to gently wipe down the surfaces, removing any dust or debris. Avoid using liquids, solvents, or abrasive cleaners, as these can damage the unit. Ensure the ventilation openings remain unobstructed for proper cooling and performance. Regular cleaning contributes to the longevity and efficiency of your UPS system.
Environmental Considerations
The APC Back-UPS Pro 1000 is designed for indoor use in a controlled environment. Operate the UPS within a temperature range of 32°F to 104°F (0°C to 40°C). Avoid exposure to direct sunlight, excessive humidity, or extreme temperatures. Responsible battery disposal is crucial; do not discard batteries with general waste – recycle them properly according to local regulations to minimize environmental impact.

Frequently Asked Questions (FAQ)
Is registration required for warranty coverage? Yes, completing and returning the warranty registration card, or registering online, is essential. What if the UPS doesn’t power on? Check the power cord and ensure the wall outlet is functioning; How do I replace the battery? The Back-UPS Pro 1000 features hot-swappable battery replacement.